Quantcast
Channel: Configuration Manager 2007 Operating System Deployment forum
Viewing all articles
Browse latest Browse all 1063

TS cannot continue after reboot

$
0
0

 

I have been working on a task sequence for the past few days and I am completely stumpped on this one.  The problem is that I can't get the Restart Computer action to work.  Everything seems to be working find, but this always give me an error.  This reboot is placed after the OS install action.  If the computer is reboot, the OS will continue to set itself up, but the Task Sequence will not run.

 

Any help would be appreciated.

Here is an excerpt from my smsts.log file

========================= [ smsboot.exe ] ========================= Reboot 4/4/2008 2:01:01 PM 2028 (0x07EC)
Command line: '"smsboot.exe" /target:HD' Reboot 4/4/2008 2:01:01 PM 2028 (0x07EC)
SMSTSRebootDelay=3 Reboot 4/4/2008 2:01:01 PM 2028 (0x07EC)
SMSTSRebootMessage=The build will restart the computer and continue to setup the OS. Reboot 4/4/2008 2:01:01 PM 2028 (0x07EC)
SMSTSRebootRequested=HD Reboot 4/4/2008 2:01:01 PM 2028 (0x07EC)
Process completed with exit code 0 TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
!--------------------------------------------------------------------------------------------! TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Successfully complete the action (Restart Computer) with the exit win32 code 0 TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Sending status message . . . TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Send a task execution status message SMS_TSExecution_ActionCompleteInfo TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
MP server DEV-SCCM.atlantis.local and port 80. SSL=false. CRL=false. TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Site code: LSA TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Client machine name: DEV-MCLANEM TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Client GUID: GUID:B014A252-3837-4F11-B929-911C3EA2AC3F TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Advertisement ID: LSA20016 TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Package ID: LSA00030 TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Sending StatusMessage TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
CLibSMSMessageWinHttpTransport:Tongue Tiedend: URL: DEV-SCCM.atlantis.local:80  CCM_POST /ccm_system/request TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Set a global environment variable _SMSTSLastActionRetCode=0 TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Set a global environment variable _SMSTSLastActionSucceeded=true TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Expand a string: %_SMSTSMDataPath%\Logs TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Clear local default environment TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Updated security on object C:\_SMSTaskSequence. TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Set a global environment variable _SMSTSNextInstructionPointer=24 TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Set a TS execution environment variable _SMSTSNextInstructionPointer=24 TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Set a global environment variable _SMSTSInstructionStackString=13 TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Set a TS execution environment variable _SMSTSInstructionStackString=13 TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Save the current environment block TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Successfully save execution state and environment to local hard disk TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Reboot to local harddisk TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
_OSDGinaIsConfigured variable set to  TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
_SMSTSServiceStartType variable set to  TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
FALSE, HRESULT=80004005 (e:\nts_sms_fre\sms\client\tasksequence\executionengine\engine.cxx,561) TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Task sequence cannot continue after reboot because TS Manager is not configured to auto-start or GINA is not installed TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
CheckForRebootRequest(&bRebootInitiated), HRESULT=80004005 (e:\nts_sms_fre\sms\client\tasksequence\executionengine\engine.cxx,274) TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Fatal error is returned in check for reboot request of the action (Restart Computer).
Unspecified error (Error: 80004005; Source: Windows) TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
An error (0x80004005) is encountered in execution of the task sequence TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Sending status message . . . TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)
Send a task execution status message SMS_TSExecution_TaskSequenceFailError TSManager 4/4/2008 2:01:01 PM 1600 (0x0640)